| Model |
MPP3120B32 |
| TOPOLOGY |
True Online Double conversion |
| CAPACITY |
20KVA/20KW – True Online Double conversion |
| PARALLEL CAPABILITY |
4 |
| INPUT |
| Nominal Voltage |
220 / 230 / 240V AC (1P+N+PE) / 380 / 400 / 415V AC (3P+N+PE) |
| Voltage Range |
120V~280V AC / 228V ~ 480V AC |
| Frequency |
40~70Hz (Auto sensing) |
| Power Factor |
≥ 0.99 @ 100% load |
| Generator Input |
Compatible |
| Input Beaker |
Shall be Available |
| OUTPUT |
| Output Voltage |
220 / 230 / 240V AC (1P+N+PE) / 380 / 400 / 415V AC (3P+N+PE) |
| AC Voltage Regulation (Batt. Mode) |
± 1% |
| Output PF |
1 |
| Frequency Range (Batt. Mode) |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio |
3:1 (max.) |
| Harmonic Distortion |
≤ 2% (Linear load) / ≤5% (Non-Linear load) |
| Transfer Time |
AC mode to Battery mode |
Zero |
| Inverter to Bypass |
Zero |
| Waveform (Batt. Mode) |
Pure Sinewave |
| Overload |
100%~110% for 60-min, 110%~125% for 10 min, 125%~150% for 1 min, >150% 200 msec |
| Cold Start function |
Available |
| Fan speed |
Load Dependent |
| ECO Mode |
Available |
| EPO |
Available |
| Efficiency |
≥ 96.0% AC Mode; ≥99.0% ECO Mode |
| Automatic Bypass |
Available |
| SYSTEM FEATURES
|
| Alarms / Protections |
Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DCBUS Under/OverVoltageandBatterylow, battery deep discharge, battery drain protection |
| Indications |
Input Voltage/frequency, Output Voltage/frequency, Load Percentage, Battery Voltage, Temperature, Remaining Battery Backup Time, Load VA/W, Load % and Battery Barograph |
| LCD Display |
7 inch Colour Touch Screen Display |
| Indications |
UPS status, Load level, Battery level, Input /Output voltage and Fault conditions |
| Display |
Input voltage, Input frequency, Output voltage, output frequency, Battery voltage, Battery level, Load level, UPS status & Fault conditions. |
| BATTERY |
| Battery Type |
VRLA (Lithium Battery Compatible) |
| DC Voltage |
480V DC |
| Battery Numbers |
30~50 pcs (Adjustable) |
| Battery Configration |
1 Nos. Battery Pack consist 20Nos. Of 12V/9AH Batteries |
| Battery Arrangement |
Battery Pack |
| Additional Battery rack compatible |
UPS should have option to be integrated with additional battery bank for future Back- up requirement |
| PHYSICAL |
| Dimension, D x W x H (mm) |
443x850x260 (6U) |
| Net Weight (Kgs) |
45 |
| Size |
19 inch Rack mountable Colour: RAL9005 |
| Ingress Protection |
IP20 |
| ENVIRONMENT |
| Operation Humidity |
0-95 % RH (non- condensing) @ 0- 40°C |
| Altitude |
No Derating @ ≤1000 Meters |
| Noise Level |
58 dB @ 1 meter |
| STANDARDS |
| Quality |
E-waste, 9001 :2015, 14001:2015, ISO 20000, TL9000 45001:2018, 27001:2013, 50001:2015 , RoHS |
| Safety |
IEC/EN62040-1 |
| EMC / Performance |
IEC/EN62040-2; IEC/EN62040-3, Complying to CE, IEC62443 |
| COMMUNICATION INTERFACE |
| Standard |
Smart RS232, USB, RS485, EPO, Dry Contact, Parallel Port |
| Optional |
SNMP / Dry Contact / IoT |
| Monitoring Software |
BPE Cyber / Muser 5000 |
Đánh giá
There are no reviews yet