Physical |
● 1RU fixed form-factor switch
● 48 10/100/1000-Mbps RJ-45 ports
● 4 1/10 Gbps SFP+ uplink ports
● 2 redundant power supplies
● 1 fan tray with redundant fans
● 1 I/O module with management, console, and USB flash memory ports
|
Performance |
● 176-Gbps switching capacity
● Forwarding rate of 132 mpps
● Line-rate traffic throughput (both Layer 2 and 3) on all ports
● Configurable Maximum Transmission Units (MTUs) of up to 9216 bytes (jumbo frames)
|
Hardware tables and scalability
|
MAC addresses
|
128,000
|
Number of VLANS
|
4096
|
Spanning-tree instances
|
● RSTP: 512
● MSTP: 64
|
ACL entries
|
2000 ingress
1000 egress
|
Routing table
|
16,000 prefixes and 16,000 host entries*
8000 multicast routes*
|
Number of EtherChannels
|
52 (with vPC)
|
Number of ports per EtherChannel
|
16
|
Buffers
|
9 MB shared
|
Boot flash memory
|
2 GB
|
Power
|
Number of power supplies
|
2 (redundant)
|
|
Typical operating power
|
120 watts (W) (48p of 1G and 4p of 10G/SR at 100% load, with 2 Power Supply Units [PSUs])
|
|
Maximum power
|
124W
|
|
AC PSUs
● Input voltage
● Frequency
● Efficiency
|
100 to 240 VAC
50 to 60 Hz
89 to 91% at 220V
|
|
DC PSUs
● Input voltage
● Maximum current
● Efficiency
|
-40 to -72 VDC
33A
85 to 88%
|
|
Typical heat dissipation
|
409 BTU/hr (48p of 1G and 4p of 10G/SR at 100% load, with 2 PSUs)
|
|
Maximum heat dissipation
|
423 BTU/hr
|
Cooling
|
Forward and reversed airflow schemes
Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)
Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies)
Single fan tray with redundant fans
Hot swappable (must swap within 1 minute)
|
Sound
|
Measured sound power (maximum)
● Fan speed: 40% duty cycle
● Fan speed: 60% duty cycle
● Fan speed: 100% duty cycle
|
63.9 dBA
64.7 dBA
66.4 dBA
|
Environment
|
Dimensions (height x width x depth)
|
1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm)
|
Weight |
20.5 lb (9.3 kg)
|
Operating temperature
|
32 to 104°F (0 to 40°C)
|
Storage temperature
|
-40 to 158°F (-40 to 70°C)
|
Operating relative humidity
|
10 to 85% noncondensing
Up to 5 days at maximum (85%) humidity
Recommend ASHRAE data center environment
|
Storage relative humidity
|
5 to 95% noncondensing
|
Altitude
|
0 to 10,000 ft (0 to 3000m)
|